Home

Products

B2B-Shop

Support

Contact

Company

News

+49 (0) 7734 936 930 78244 Gottmadingen - GERMANY

ULTRA3 ATEX LED ex-proof floodlight

 

Robust EX LED spotlight | 24 volts - 48 volts


Safeboy Symbole LED Strahler


Immerse yourself in the world of the explosion-proof LED spotlight Ultra3 - the latest innovation that has surpassed the proven Ultra1 model. This advanced ATEX LED spotlight combines outstanding light output with unsurpassed mobility, making it the ultimate lighting solution for demanding and harsh environments where explosion protection is required. (EX zones 1, 2, 21 and 22)

Robust, reliable and flexible in use
The explosion-proof Ultra3 LED spotlight is not only an upgrade of its predecessor, but also sets new standards in terms of lightness and robustness. Its low weight makes it particularly flexible and at the same time it impresses with its extraordinary stability. This combination makes the spotlight the optimal choice for applications where mobile lighting is required in challenging environments. For even more versatility, optional accessories such as a telescopic tripod, hanging hook or magnetic attachment are available.

81 POWER LEDs - high light output
The ATEX spotlight is available for connection voltages from 24 volts to 48 volts AC/DC and therefore offers a wide range of application flexibility. With 81 POWER LEDs and a light color of 5000 Kelvin, the spotlight provides wide and even illumination. The short switch-on time, long service life and low energy consumption make the Ultra3 a cost-efficient and sustainable lighting solution.

Dust-tight and jet-proof
With a high protection level of IP65, the LED spotlight is dustproof and water jet-proof, which underlines its reliability and longevity. The H07RN-F supply cable with a standard length of 10 meters (optionally 30 meters) offers additional flexibility during installation.

Overall, the explosion-proof Ultra3 LED spotlight is an outstanding light source that not only represents technological advances, but also meets the highest standards in terms of mobility, safety and performance. With its wide range of applications and optional accessory options, it is the perfect choice for professional lighting in challenging environments.

alternatively available: rechargeable version ULTRA XL


ATEX Identification

EX Symbol II 2 G  Ex ib mb IIC T4 Gb | Tool group: II | Hazardous zone: 1 and 2, 21 and 22
EX Symbol II 2 D  Ex ib mb IIIC T130° Db | Category: 2G and 2D | Temperature class T4

Explanation: II 2 G Ex ib mb IIC T4 Gb

The ATEX marking II 2 G Ex ib mb IIC T4 Gb describes the specific features of a device suitable for use in explosive atmospheres. This marking provides detailed information about the protection types and the application scope of the device. Here is a detailed explanation of each component:

1. II 2 G
II: Equipment group II – The device is suitable for use in explosive atmospheres outside of mining, such as in the chemical industry, refineries, or areas with flammable gases.
2: Category 2 – The device provides a high level of protection and is suitable for areas where an explosive atmosphere due to gases may occasionally occur. Category 2 devices are intended for use in Zone 1, where an explosive atmosphere is expected to occur during normal operation.
G: Gas – The device is certified for use in areas where gas, vapor, or mist can form an explosive atmosphere.

2. Ex
This means "explosion-proof" and indicates that the device has been certified in accordance with the ATEX directive requirements.

3. ib
ib: Intrinsic safety – This protection method ensures that the electrical circuits of the device are designed to prevent sparks or thermal effects that could ignite an explosive atmosphere. The ib protection type is suitable for use in Zone 1, where explosive atmospheres may occasionally occur.

4. mb
mb: Encapsulation – This protection method ensures that electrical components are housed in an encapsulated or potted enclosure, preventing contact with an explosive atmosphere. This helps avoid potential ignition sources.

5. IIC
IIC: Gas group – This indicates that the device is certified for use with the most dangerous and easily ignitable gases, such as hydrogen and acetylene. IIC represents the highest hazard level in the gas group classification.

6. T4
T4: Temperature class – This indicates the maximum surface temperature of the device. T4 means the device will not exceed a surface temperature of 135°C. Devices with a T4 rating are safe to use with many flammable gases, as this temperature is below the ignition point of most gases.

7. Gb
Gb: Equipment protection level – The Gb level indicates that the device can be used in areas where an explosive atmosphere is likely to occur during normal operation (Zone 1). Gb provides a high level of protection, though slightly lower than the highest level, Ga.

Summary:
The device is suitable for use in Zone 1, where explosive gas atmospheres may occasionally occur.
It offers protection through intrinsic safety (ib) and encapsulation (mb), ensuring that no ignition sources arise from electrical components or surface temperatures.
It is approved for use in the most hazardous gas atmospheres of group IIC.
The maximum surface temperature is 135°C (T4), preventing ignition from hot surfaces.
This device is specifically designed for use in explosive gas environments and provides comprehensive protection against potential ignition sources.

Explanation: II 2 D Ex ib mb IIIC T135°C Db

The ATEX marking II 2 D Ex ib mb IIIC T135°C Db describes the characteristics of a device certified for use in explosive atmospheres, particularly in areas where dust can create a potentially explosive environment. Here is a detailed explanation of the individual components:

1. II 2 D
II: Equipment group II – The device is suitable for use in explosive atmospheres outside of mining, such as in food processing, mills, chemical plants, etc.
2: Category 2 – The device provides a high level of protection and is suitable for areas where an explosive atmosphere due to dust may occasionally occur. It is intended for use in Zone 21, where an explosive dust atmosphere is expected to occur during normal operation.
D: Dust – The device is certified for use in dust-explosive environments.

2. Ex
This stands for "explosion-proof" and indicates that the device has been tested and certified according to the ATEX directive requirements.

3. ib
ib: Intrinsic safety – This protection method ensures that the electrical circuits of the device are designed to prevent sparks or thermal effects that could ignite a dust atmosphere. ib is certified for use in Zone 21, where explosive dust atmospheres may occasionally occur.

4. mb
mb: Encapsulation – This protection method ensures that electrical components are housed in a potted or encapsulated enclosure, preventing dust from entering the electronics and causing ignition. This helps avoid the creation of ignition sources from electrical components.

5. IIIC
IIIC: Dust group – This classification indicates that the device is suitable for use with conductive dust, which can be particularly dangerous (e.g., metal dust). IIIC is the highest dust group, covering both conductive and non-conductive dusts (IIIA and IIIB).

6. T135°C
T135°C: Temperature class – This indicates the maximum surface temperature of the device. T135°C means the surface temperature of the device will not exceed 135°C. This is important because dust can settle on surfaces and ignite if the temperature is too high. This classification ensures the device does not reach a temperature that could trigger a dust explosion.

7. Db
Db: Equipment protection level – This protection level indicates that the device is suitable for use in Zone 21, where explosive dust atmospheres are likely during normal operation. Db offers a high level of protection, though slightly lower than the highest protection level Da.

Summary:
The device is suitable for use in dust-explosive environments (Zone 21).
It provides protection through intrinsic safety (ib) and encapsulation (mb), preventing dust from entering the electronics or creating ignition sources.
It is certified for use with conductive dust (IIIC), considered particularly hazardous.
The device's maximum surface temperature is 135°C, ensuring that settled dust will not ignite.
The Db protection level provides a high degree of safety for use in areas where dust atmospheres are regularly present.
This device is specifically designed for use in explosive dust environments and ensures comprehensive protection against potential ignition sources and explosions.


Highlights

  • Robust LED spotlight, with 81 POWER LEDs, 5000K
  • Voltage: 24V - 48V AC / DC
  • Width, even illumination
  • Short on-time / long life / low energy consumption
  • Plastic housing, antistatic, (polypropylen)
  • Positionable horizontally or vertically
  • Protection category IP65
  • Cable 10m H07RN-F (opt. 30m)
  • Standard version without plug, Ex plug (ATX, CEAG, steel) available on request


Areas of application

LED spotlights for construction sites

Building Industry

LED spotlights as temporary lighting on construction sites, also available with emergency function.

LED spotlights for industry

Petrochemistry

LED spotlight in EX version for mobile, temporary lighting in areas where EX protection is required.

LED spotlights for shipbuilding and shipyards

Shipyards

LED spotlight can be used for large area illumination, e.g. in shipyards.

 

Accessoires

 

Hanging devices for EX lights KIRA Leuchten GmbH - lighting accessories

EX suspension devices

For easy and fast attachment of mobile work lights.
 
Telescopic tripod for EX lights KIRA Leuchten GmbH - lighting accessories

EX Tripod & Stand

High-quality stand devices for luminaires and spotlights.
 
Mounting clips and magnets for EX lights KIRA Leuchten GmbH - lighting accessories

Brackets & magnets

Mounting clamps for fast and secure fastening of tube lights.
 
 

Solutions

 

explosion-proof lighting cart/trolley KIRA Leuchten GmbH - lighting accessories

EX Trolly

Mobile lighting solution for ex-proof areas. Available with fluorescent or LED lamps.
 
explosion-proof battery pack KIRA Leuchten GmbH - lighting accessories

EX battery Pack

The explosion-proof battery pack is ideal for mobile use in conjunction with our explosion-proof lights in 24V design.
 
ex-geschützte Komplett-Sets / Leuchten inklusive ATEX Trafo KIRA Leuchten GmbH - complete sets

Complete-Sets